SIMATIC S7-400,6ES7416-3XR05-0AB0

March 8, 2018 0

SIMATIC S7-400, CPU 416-3 CENTRAL PROCESSING UNIT WITH: 11.2 MB WORKING MEMORY, (5.6 MB CODE, 5.6 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3. IF IFM MODULES PLUGGABLE

Description

General information
Product type designation CPU 416-3
HW functional status 04
Firmware version V5.3
Engineering with
● Programming package STEP 7 V5.3 SP2 or higher with HW update
CiR – Configuration in RUN
CiR synchronization time, basic load 100 ms
CiR synchronization time, time per I/O byte 10 µs
Supply voltage
Rated value (DC)
● 24 V DC No; Power supply via system power supply
Input current
from backplane bus 5 V DC, typ. 1.1 A
from backplane bus 5 V DC, max. 1.3 A
from backplane bus 24 V DC, max. 450 mA; 150 mA per DP interface
from interface 5 V DC, max. 90 mA; At each DP interface
Power loss
Power loss, typ. 5.5 W
Power loss, max. 6 W
Memory
Type of memory RAM
Work memory
● integrated 11.2 Mbyte
● integrated (for program) 5.6 Mbyte
● integrated (for data) 5.6 Mbyte
● expandable No
Load memory
● expandable FEPROM Yes; with Memory Card (FLASH)
● expandable FEPROM, max. 64 Mbyte
● integrated RAM, max. 1 Mbyte
● expandable RAM Yes; with Memory Card (RAM)
● expandable RAM, max. 64 Mbyte
Backup
● present Yes
● with battery Yes; all data
● without battery No
Battery
Backup battery
● Backup current, typ. 125 µA; up to 40 °C
● Backup current, max. 550 µA
● Backup time, max. See reference manual, module data, Chapter 3.3
● Feeding of external backup voltage to CPU 5 V DC to 15 V DC
CPU processing times
for bit operations, typ. 30 ns
for word operations, typ. 30 ns
for fixed point arithmetic, typ. 30 ns
for floating point arithmetic, typ. 90 ns
CPU-blocks
DB
● Number, max. 10 000; Number range: 1 to 16000
● Size, max. 64 kbyte
FB
● Number, max. 5 000; Number range: 0 to 7999
● Size, max. 64 kbyte
FC
● Number, max. 5 000; Number range: 0 to 7999
● Size, max. 64 kbyte
OB
● Number, max. see instruction list
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 8; OB 10-17
● Number of delay alarm OBs 4; OB 20-23
● Number of cyclic interrupt OBs 9; OB 30-38 (shortest cycle that can be set = 500 µs)
● Number of process alarm OBs 8; OB 40-47
● Number of DPV1 alarm OBs 3; OB 55-57
● Number of isochronous mode OBs 4; OB 61-64
● Number of multicomputing OBs 1; OB 60
● Number of background OBs 1; OB 90
● Number of startup OBs 3; OB 100-102
● Number of asynchronous error OBs 9; OB 80-88
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 24
● additional within an error OB 2
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
— lower limit 0
— upper limit 2 047
— preset Z 0 to Z 7
Counting range
— lower limit 0
— upper limit 999
IEC counter
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 2 048
Retentivity
— adjustable Yes
— lower limit 0
— upper limit 2 047
— preset No times retentive
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in total Total working and load memory (with backup battery)
Flag
● Number, max. 16 kbyte; Size of bit memory address area
● Retentivity available Yes
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; in 1 memory byte
Local data
● adjustable, max. 32 kbyte
● preset 16 kbyte
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which distributed
— MPI/DP interface, inputs 2 kbyte
— MPI/DP interface, outputs 2 kbyte
— DP interface, inputs 8 kbyte
— DP interface, outputs 8 kbyte
Process image
● Inputs, adjustable 16 kbyte
● Outputs, adjustable 16 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
● consistent data, max. 244 byte
● Access to consistent data in process image Yes
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 131 072
— of which central 131 072
● Outputs 131 072
— of which central 131 072
Analog channels
● Inputs 8 192
— of which central 8 192
● Outputs 8 192
— of which central 8 192
Hardware configuration
Number of expansion units, max. 21
connectable OPs 63
Multicomputing Yes; 4 CPUs max. (with UR1 or UR2)
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 4; IM 463-2
Number of DP masters
● integrated 2
● via CP 10; CP 443-5 Extended
● via IM 467 4
● Mixed mode IM + CP permitted No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
● via interface module 1
● Number of pluggable S5 modules (via adapter capsule in central device), max. 6
Number of IO Controllers
● integrated 0
● via CP 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended)
● FM Limited by number of slots and number of connections
● CP, PtP CP 440: Limited by number of slots; CP 441: limited by number of connections
● PROFIBUS and Ethernet CPs 14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
Slots
● required slots 2
Time of day
Clock
● Hardware clock (real-time) Yes
● retentive and synchronizable Yes
● Resolution 1 ms
● Deviation per day (buffered), max. 1.7 s; Power off
● Deviation per day (unbuffered), max. 8.6 s; For power On
Operating hours counter
● Number 16
● Number/Number range 0 to 15
● Range of values SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours
● Granularity 1 hour
● retentive Yes
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP No; Via CP
● to IF 964 DP Yes
Time difference in system when synchronizing via
● MPI, max. 200 ms
Interfaces
Interfaces/bus type 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable)
Number of RS 485 interfaces 2
Number of other interfaces 0
1. Interface
Interface type Integrated
Physics RS 485 / PROFIBUS + MPI
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Number of connection resources MPI: 44, DP: 32
Functionality
● MPI Yes
● PROFIBUS DP master Yes
● PROFIBUS DP slave Yes
MPI
● Number of connections 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
DP master
● Number of connections, max. 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● GSD file http://support.automation.siemens.com/WW/view/en/113652
● Transmission rate, max. 12 Mbit/s
● automatic baud rate search No
● Address area, max. 32; Virtual slots
● User data per address area, max. 32 byte
— of which consistent, max. 32 byte
Services
— PG/OP communication Yes; with interface active
— Routing Yes; with interface active
— S7 routing Yes; with interface active
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) No
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2. Interface
Interface type Integrated
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Number of connection resources 32
Functionality
● PROFIBUS DP master Yes
● PROFIBUS DP slave Yes
DP master
● Number of connections, max. 32
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● GSD file http://support.automation.siemens.com/WW/view/en/113652
● Transmission rate, max. 12 Mbit/s
● Address area, max. 32
● User data per address area, max. 32 byte
— of which consistent, max. 32 byte
Services
— Routing Yes
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
3. Interface
Interface type Pluggable interface module (IF), technical data as for 2nd interface
Plug-in interface modules IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
automatic detection of transmission rate No
Number of connection resources 32
Functionality
● MPI No
● PROFIBUS DP master Yes
● PROFIBUS DP slave Yes
DP master
● Number of connections, max. 32
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes; S7 routing
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● GSD file http://support.automation.siemens.com/WW/view/en/113652
● Transmission rate, max. 12 Mbit/s
● automatic baud rate search No
● Address area, max. 32
● User data per address area, max. 32 byte
— of which consistent, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; with interface active
— S7 routing Yes; with interface active
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) No
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
Protocols
Open IE communication
● ISO-on-TCP (RFC1006) Via CP 443-1 and loadable FB
— Data length, max. 1452 bytes via CP 443-1 Adv.
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes; For PROFIBUS only
Equidistance Yes
Number of DP masters with isochronous mode 3
User data per isochronous slave, max. 244 byte
shortest clock pulse 1 ms; 0.5 ms without use of SFC 126, 127
max. cycle 32 ms
Communication functions
PG/OP communication Yes
● Number of connectable OPs without message processing 63
● Number of connectable OPs with message processing 63; When using Alarm_S/SQ and Alarm_D/DQ
Data record routing Yes
Global data communication
● supported Yes
● Number of GD loops, max. 16
● Number of GD packets, transmitter, max. 16
● Number of GD packets, receiver, max. 32
● Size of GD packets, max. 54 byte
● Size of GD packet (of which consistent), max. 1 variable
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 1 variable
S7 communication
● supported Yes
● as server Yes
● as client Yes
● User data per job, max. 64 kbyte
● User data per job (of which consistent), max. 462 byte; 1 variable
S5 compatible communication
● supported Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
● User data per job, max. 8 kbyte
● User data per job (of which consistent), max. 240 byte
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. 64/64
Standard communication (FMS)
● supported Yes; Via CP and loadable FB
Web server
● supported No
Number of connections
● overall 64
● usable for PG communication 63
— reserved for PG communication 1
— adjustable for PG communication, max. 0
● usable for OP communication 63
— reserved for OP communication 1
— adjustable for OP communication, max. 0
● usable for S7 basic communication 62
— reserved for S7 basic communication 0
— adjustable for S7 basic communication, max. 0
● usable for S7 communication 62
— reserved for S7 communication 0
— adjustable for S7 communication, max. 0
● usable for routing 31
— reserved for routing 0
— adjustable for routing, max. 0
S7 message functions
Number of login stations for message functions, max. 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Symbol-related messages Yes
SCAN procedure Yes
Program alarms Yes
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 4 000
● preset, max. 600
Process control messages Yes
Number of archives that can log on simultaneously (SFB 37 AR_SEND) 32
Number of messages
● overall, max. 1 024
● in 100 ms grid, max. 128
● in 500 ms grid, max. 512
● in 1000 ms grid, max. 1 024
Number of additional values
● with 100 ms grid, max. 1
● with 500, 1000 ms grid, max. 10
Test commissioning functions
Status block Yes; Up to 2 simultaneously
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable Yes; Up to 16 variable tables
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max. 70; Status/control
Forcing
● Forcing Yes
● Forcing, variables Inputs, outputs, bit memories, peripheral inputs, peripheral outputs
● Number of variables, max. 512
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— adjustable Yes
— preset 120
Service data
● can be read out Yes
Standards, approvals, certificates
CE mark Yes
CSA approval Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
Use in hazardous areas
● ATEX ATEX II 3G Ex nA IIC T4 Gc
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 60 °C
Configuration
Configuration software
● STEP 7 Yes
Programming
● Command set see instruction list
● Nesting levels 7
● Access to consistent data in process image Yes
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Number of simultaneously active SFCs
— DPSYC_FR 2; SFC 11; per interface
— D_ACT_DP 8; SFC 12; per interface
— RD_REC 8; SFC 59; per interface
— WR_REC 8; SFC 58; per interface
— WR_PARM 8; SFC 55; per interface
— PARM_MOD 1; SFC 57; per interface
— WR_DPARM 2; SFC 56; per interface
— DPNRM_DG 8; SFC 13; per interface
— RDSYSST 8
— DP_TOPOL 1; SFC 103; per interface
Number of simultaneously active SFBs
— RDREC 8; SFB 52; per interface, but not more than 32 across all external interfaces
— WRREC 8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Weights
Weight, approx. 900 g
last modified: 03/05/2018