SIMATIC S7-400,6ES7416-3XR05-0AB0
SIMATIC S7-400, CPU 416-3 CENTRAL PROCESSING UNIT WITH: 11.2 MB WORKING MEMORY, (5.6 MB CODE, 5.6 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3. IF IFM MODULES PLUGGABLE
Description
General information | ||
Product type designation | CPU 416-3 | |
HW functional status | 04 | |
Firmware version | V5.3 | |
Engineering with | ||
● Programming package | STEP 7 V5.3 SP2 or higher with HW update | |
CiR – Configuration in RUN | ||
CiR synchronization time, basic load | 100 ms | |
CiR synchronization time, time per I/O byte | 10 µs | |
Supply voltage | ||
Rated value (DC) | ||
● 24 V DC | No; Power supply via system power supply | |
Input current | ||
from backplane bus 5 V DC, typ. | 1.1 A | |
from backplane bus 5 V DC, max. | 1.3 A | |
from backplane bus 24 V DC, max. | 450 mA; 150 mA per DP interface | |
from interface 5 V DC, max. | 90 mA; At each DP interface | |
Power loss | ||
Power loss, typ. | 5.5 W | |
Power loss, max. | 6 W | |
Memory | ||
Type of memory | RAM | |
Work memory | ||
● integrated | 11.2 Mbyte | |
● integrated (for program) | 5.6 Mbyte | |
● integrated (for data) | 5.6 Mbyte | |
● expandable | No | |
Load memory | ||
● expandable FEPROM | Yes; with Memory Card (FLASH) | |
● expandable FEPROM, max. | 64 Mbyte | |
● integrated RAM, max. | 1 Mbyte | |
● expandable RAM | Yes; with Memory Card (RAM) | |
● expandable RAM, max. | 64 Mbyte | |
Backup | ||
● present | Yes | |
● with battery | Yes; all data | |
● without battery | No | |
Battery | ||
Backup battery | ||
● Backup current, typ. | 125 µA; up to 40 °C | |
● Backup current, max. | 550 µA | |
● Backup time, max. | See reference manual, module data, Chapter 3.3 | |
● Feeding of external backup voltage to CPU | 5 V DC to 15 V DC | |
CPU processing times | ||
for bit operations, typ. | 30 ns | |
for word operations, typ. | 30 ns | |
for fixed point arithmetic, typ. | 30 ns | |
for floating point arithmetic, typ. | 90 ns | |
CPU-blocks | ||
DB | ||
● Number, max. | 10 000; Number range: 1 to 16000 | |
● Size, max. | 64 kbyte | |
FB | ||
● Number, max. | 5 000; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
FC | ||
● Number, max. | 5 000; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
OB | ||
● Number, max. | see instruction list | |
● Size, max. | 64 kbyte | |
● Number of free cycle OBs | 1; OB 1 | |
● Number of time alarm OBs | 8; OB 10-17 | |
● Number of delay alarm OBs | 4; OB 20-23 | |
● Number of cyclic interrupt OBs | 9; OB 30-38 (shortest cycle that can be set = 500 µs) | |
● Number of process alarm OBs | 8; OB 40-47 | |
● Number of DPV1 alarm OBs | 3; OB 55-57 | |
● Number of isochronous mode OBs | 4; OB 61-64 | |
● Number of multicomputing OBs | 1; OB 60 | |
● Number of background OBs | 1; OB 90 | |
● Number of startup OBs | 3; OB 100-102 | |
● Number of asynchronous error OBs | 9; OB 80-88 | |
● Number of synchronous error OBs | 2; OB 121, 122 | |
Nesting depth | ||
● per priority class | 24 | |
● additional within an error OB | 2 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 2 047 | |
— preset | Z 0 to Z 7 | |
Counting range | ||
— lower limit | 0 | |
— upper limit | 999 | |
IEC counter | ||
● Number | Unlimited (limited only by RAM capacity) | |
S7 times | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 2 047 | |
— preset | No times retentive | |
Time range | ||
— lower limit | 10 ms | |
— upper limit | 9 990 s | |
IEC timer | ||
● present | Yes | |
● Type | SFB | |
● Number | Unlimited (limited only by RAM capacity) | |
Data areas and their retentivity | ||
retentive data area in total | Total working and load memory (with backup battery) | |
Flag | ||
● Number, max. | 16 kbyte; Size of bit memory address area | |
● Retentivity available | Yes | |
● Retentivity preset | MB 0 to MB 15 | |
● Number of clock memories | 8; in 1 memory byte | |
Local data | ||
● adjustable, max. | 32 kbyte | |
● preset | 16 kbyte | |
Address area | ||
I/O address area | ||
● Inputs | 16 kbyte | |
● Outputs | 16 kbyte | |
of which distributed | ||
— MPI/DP interface, inputs | 2 kbyte | |
— MPI/DP interface, outputs | 2 kbyte | |
— DP interface, inputs | 8 kbyte | |
— DP interface, outputs | 8 kbyte | |
Process image | ||
● Inputs, adjustable | 16 kbyte | |
● Outputs, adjustable | 16 kbyte | |
● Inputs, default | 512 byte | |
● Outputs, default | 512 byte | |
● consistent data, max. | 244 byte | |
● Access to consistent data in process image | Yes | |
Subprocess images | ||
● Number of subprocess images, max. | 15 | |
Digital channels | ||
● Inputs | 131 072 | |
— of which central | 131 072 | |
● Outputs | 131 072 | |
— of which central | 131 072 | |
Analog channels | ||
● Inputs | 8 192 | |
— of which central | 8 192 | |
● Outputs | 8 192 | |
— of which central | 8 192 | |
Hardware configuration | ||
Number of expansion units, max. | 21 | |
connectable OPs | 63 | |
Multicomputing | Yes; 4 CPUs max. (with UR1 or UR2) | |
Interface modules | ||
● Number of connectable IMs (total), max. | 6 | |
● Number of connectable IM 460s, max. | 6 | |
● Number of connectable IM 463s, max. | 4; IM 463-2 | |
Number of DP masters | ||
● integrated | 2 | |
● via CP | 10; CP 443-5 Extended | |
● via IM 467 | 4 | |
● Mixed mode IM + CP permitted | No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode) | |
● via interface module | 1 | |
● Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 | |
Number of IO Controllers | ||
● integrated | 0 | |
● via CP | 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller | |
Number of operable FMs and CPs (recommended) | ||
● FM | Limited by number of slots and number of connections | |
● CP, PtP | CP 440: Limited by number of slots; CP 441: limited by number of connections | |
● PROFIBUS and Ethernet CPs | 14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum | |
Slots | ||
● required slots | 2 | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
● retentive and synchronizable | Yes | |
● Resolution | 1 ms | |
● Deviation per day (buffered), max. | 1.7 s; Power off | |
● Deviation per day (unbuffered), max. | 8.6 s; For power On | |
Operating hours counter | ||
● Number | 16 | |
● Number/Number range | 0 to 15 | |
● Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 – 1 hours | |
● Granularity | 1 hour | |
● retentive | Yes | |
Clock synchronization | ||
● supported | Yes | |
● to MPI, master | Yes | |
● to MPI, slave | Yes | |
● to DP, master | Yes | |
● to DP, slave | Yes | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | No; Via CP | |
● to IF 964 DP | Yes | |
Time difference in system when synchronizing via | ||
● MPI, max. | 200 ms | |
Interfaces | ||
Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable) | |
Number of RS 485 interfaces | 2 | |
Number of other interfaces | 0 | |
1. Interface | ||
Interface type | Integrated | |
Physics | RS 485 / PROFIBUS + MPI | |
Isolated | Yes | |
Power supply to interface (15 to 30 V DC), max. | 150 mA | |
Number of connection resources | MPI: 44, DP: 32 | |
Functionality | ||
● MPI | Yes | |
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | Yes | |
MPI | ||
● Number of connections | 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | |
● Transmission rate, max. | 12 Mbit/s | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | Yes | |
— S7 basic communication | Yes | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
DP master | ||
● Number of connections, max. | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | |
● Transmission rate, max. | 12 Mbit/s | |
● Number of DP slaves, max. | 32 | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | No | |
— S7 basic communication | Yes | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
— Equidistance | Yes | |
— Isochronous mode | Yes | |
— SYNC/FREEZE | Yes | |
— Activation/deactivation of DP slaves | Yes | |
— Direct data exchange (slave-to-slave communication) | Yes | |
— DPV1 | Yes | |
Address area | ||
— Inputs, max. | 2 kbyte | |
— Outputs, max. | 2 kbyte | |
User data per DP slave | ||
— User data per DP slave, max. | 244 byte | |
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
— Slots, max. | 244 | |
— per slot, max. | 128 byte | |
DP slave | ||
● Number of connections | 32 | |
● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | |
● Transmission rate, max. | 12 Mbit/s | |
● automatic baud rate search | No | |
● Address area, max. | 32; Virtual slots | |
● User data per address area, max. | 32 byte | |
— of which consistent, max. | 32 byte | |
Services | ||
— PG/OP communication | Yes; with interface active | |
— Routing | Yes; with interface active | |
— S7 routing | Yes; with interface active | |
— Global data communication | No | |
— S7 basic communication | No | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
— Direct data exchange (slave-to-slave communication) | No | |
— DPV1 | No | |
Transfer memory | ||
— Inputs | 244 byte | |
— Outputs | 244 byte | |
2. Interface | ||
Interface type | Integrated | |
Physics | RS 485 / PROFIBUS | |
Isolated | Yes | |
Power supply to interface (15 to 30 V DC), max. | 150 mA | |
Number of connection resources | 32 | |
Functionality | ||
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | Yes | |
DP master | ||
● Number of connections, max. | 32 | |
● Transmission rate, max. | 12 Mbit/s | |
● Number of DP slaves, max. | 125 | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | No | |
— S7 basic communication | Yes | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
— Equidistance | Yes | |
— Isochronous mode | Yes | |
— SYNC/FREEZE | Yes | |
— Activation/deactivation of DP slaves | Yes | |
— Direct data exchange (slave-to-slave communication) | Yes | |
— DPV1 | Yes | |
Address area | ||
— Inputs, max. | 8 kbyte | |
— Outputs, max. | 8 kbyte | |
User data per DP slave | ||
— User data per DP slave, max. | 244 byte | |
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
— Slots, max. | 244 | |
— per slot, max. | 128 byte | |
DP slave | ||
● Number of connections | 32 | |
● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | |
● Transmission rate, max. | 12 Mbit/s | |
● Address area, max. | 32 | |
● User data per address area, max. | 32 byte | |
— of which consistent, max. | 32 byte | |
Services | ||
— Routing | Yes | |
Transfer memory | ||
— Inputs | 244 byte | |
— Outputs | 244 byte | |
3. Interface | ||
Interface type | Pluggable interface module (IF), technical data as for 2nd interface | |
Plug-in interface modules | IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) | |
Physics | RS 485 / PROFIBUS | |
Isolated | Yes | |
Power supply to interface (15 to 30 V DC), max. | 150 mA | |
automatic detection of transmission rate | No | |
Number of connection resources | 32 | |
Functionality | ||
● MPI | No | |
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | Yes | |
DP master | ||
● Number of connections, max. | 32 | |
● Number of DP slaves, max. | 125 | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes; S7 routing | |
— Global data communication | No | |
— S7 basic communication | No | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
— Equidistance | Yes | |
— Isochronous mode | Yes | |
— SYNC/FREEZE | Yes | |
— Activation/deactivation of DP slaves | Yes | |
— Direct data exchange (slave-to-slave communication) | Yes | |
— DPV0 | Yes | |
— DPV1 | Yes | |
Address area | ||
— Inputs, max. | 8 kbyte | |
— Outputs, max. | 8 kbyte | |
User data per DP slave | ||
— User data per DP slave, max. | 244 byte | |
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
— Slots, max. | 244 | |
— per slot, max. | 128 byte | |
DP slave | ||
● Number of connections | 32 | |
● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | |
● Transmission rate, max. | 12 Mbit/s | |
● automatic baud rate search | No | |
● Address area, max. | 32 | |
● User data per address area, max. | 32 byte | |
— of which consistent, max. | 32 byte | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes; with interface active | |
— S7 routing | Yes; with interface active | |
— Global data communication | No | |
— S7 basic communication | No | |
— S7 communication | Yes | |
— S7 communication, as client | Yes | |
— S7 communication, as server | Yes | |
— Direct data exchange (slave-to-slave communication) | No | |
— DPV1 | No | |
Transfer memory | ||
— Inputs | 244 byte | |
— Outputs | 244 byte | |
Protocols | ||
Open IE communication | ||
● ISO-on-TCP (RFC1006) | Via CP 443-1 and loadable FB | |
— Data length, max. | 1452 bytes via CP 443-1 Adv. | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | Yes; For PROFIBUS only | |
Equidistance | Yes | |
Number of DP masters with isochronous mode | 3 | |
User data per isochronous slave, max. | 244 byte | |
shortest clock pulse | 1 ms; 0.5 ms without use of SFC 126, 127 | |
max. cycle | 32 ms | |
Communication functions | ||
PG/OP communication | Yes | |
● Number of connectable OPs without message processing | 63 | |
● Number of connectable OPs with message processing | 63; When using Alarm_S/SQ and Alarm_D/DQ | |
Data record routing | Yes | |
Global data communication | ||
● supported | Yes | |
● Number of GD loops, max. | 16 | |
● Number of GD packets, transmitter, max. | 16 | |
● Number of GD packets, receiver, max. | 32 | |
● Size of GD packets, max. | 54 byte | |
● Size of GD packet (of which consistent), max. | 1 variable | |
S7 basic communication | ||
● supported | Yes | |
● User data per job, max. | 76 byte | |
● User data per job (of which consistent), max. | 1 variable | |
S7 communication | ||
● supported | Yes | |
● as server | Yes | |
● as client | Yes | |
● User data per job, max. | 64 kbyte | |
● User data per job (of which consistent), max. | 462 byte; 1 variable | |
S5 compatible communication | ||
● supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | |
● User data per job, max. | 8 kbyte | |
● User data per job (of which consistent), max. | 240 byte | |
● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 64/64 | |
Standard communication (FMS) | ||
● supported | Yes; Via CP and loadable FB | |
Web server | ||
● supported | No | |
Number of connections | ||
● overall | 64 | |
● usable for PG communication | 63 | |
— reserved for PG communication | 1 | |
— adjustable for PG communication, max. | 0 | |
● usable for OP communication | 63 | |
— reserved for OP communication | 1 | |
— adjustable for OP communication, max. | 0 | |
● usable for S7 basic communication | 62 | |
— reserved for S7 basic communication | 0 | |
— adjustable for S7 basic communication, max. | 0 | |
● usable for S7 communication | 62 | |
— reserved for S7 communication | 0 | |
— adjustable for S7 communication, max. | 0 | |
● usable for routing | 31 | |
— reserved for routing | 0 | |
— adjustable for routing, max. | 0 | |
S7 message functions | ||
Number of login stations for message functions, max. | 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) | |
Symbol-related messages | Yes | |
SCAN procedure | Yes | |
Program alarms | Yes | |
Process diagnostic messages | Yes | |
simultaneously active Alarm-S blocks, max. | 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks | |
Alarm 8-blocks | Yes | |
● Number of instances for alarm 8 and S7 communication blocks, max. | 4 000 | |
● preset, max. | 600 | |
Process control messages | Yes | |
Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 32 | |
Number of messages | ||
● overall, max. | 1 024 | |
● in 100 ms grid, max. | 128 | |
● in 500 ms grid, max. | 512 | |
● in 1000 ms grid, max. | 1 024 | |
Number of additional values | ||
● with 100 ms grid, max. | 1 | |
● with 500, 1000 ms grid, max. | 10 | |
Test commissioning functions | ||
Status block | Yes; Up to 2 simultaneously | |
Single step | Yes | |
Number of breakpoints | 4 | |
Status/control | ||
● Status/control variable | Yes; Up to 16 variable tables | |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | |
● Number of variables, max. | 70; Status/control | |
Forcing | ||
● Forcing | Yes | |
● Forcing, variables | Inputs, outputs, bit memories, peripheral inputs, peripheral outputs | |
● Number of variables, max. | 512 | |
Diagnostic buffer | ||
● present | Yes | |
● Number of entries, max. | 3 200 | |
— adjustable | Yes | |
— preset | 120 | |
Service data | ||
● can be read out | Yes | |
Standards, approvals, certificates | ||
CE mark | Yes | |
CSA approval | Yes | |
UL approval | Yes | |
cULus | Yes | |
FM approval | Yes | |
RCM (formerly C-TICK) | Yes | |
KC approval | Yes | |
EAC (formerly Gost-R) | Yes | |
Use in hazardous areas | ||
● ATEX | ATEX II 3G Ex nA IIC T4 Gc | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | 0 °C | |
● max. | 60 °C | |
Configuration | ||
Configuration software | ||
● STEP 7 | Yes | |
Programming | ||
● Command set | see instruction list | |
● Nesting levels | 7 | |
● Access to consistent data in process image | Yes | |
● System functions (SFC) | see instruction list | |
● System function blocks (SFB) | see instruction list | |
Programming language | ||
— LAD | Yes | |
— FBD | Yes | |
— STL | Yes | |
— SCL | Yes | |
— CFC | Yes | |
— GRAPH | Yes | |
— HiGraph® | Yes | |
Number of simultaneously active SFCs | ||
— DPSYC_FR | 2; SFC 11; per interface | |
— D_ACT_DP | 8; SFC 12; per interface | |
— RD_REC | 8; SFC 59; per interface | |
— WR_REC | 8; SFC 58; per interface | |
— WR_PARM | 8; SFC 55; per interface | |
— PARM_MOD | 1; SFC 57; per interface | |
— WR_DPARM | 2; SFC 56; per interface | |
— DPNRM_DG | 8; SFC 13; per interface | |
— RDSYSST | 8 | |
— DP_TOPOL | 1; SFC 103; per interface | |
Number of simultaneously active SFBs | ||
— RDREC | 8; SFB 52; per interface, but not more than 32 across all external interfaces | |
— WRREC | 8; SFB 53; per interface, but not more than 32 across all external interfaces | |
Know-how protection | ||
● User program protection/password protection | Yes | |
Dimensions | ||
Width | 50 mm | |
Height | 290 mm | |
Depth | 219 mm | |
Weights | ||
Weight, approx. | 900 g | |
last modified: | 03/05/2018 |