ProfiNet Communications processor CP 443-1 ,6GK7443-1EX20-0XE0
Communications processor CP 443-1 for connection of SIMATIC S7-400 to industrial Ethernet over ISO, TCP/IP and UDP, S7 communication, fetch/write, SEND/RECEIVE with and without RFC1006 Multicast, PROFINET IO Controller, DHCP, SNMP V2, Web, diagnostics, initialization via LAN, access protection via IP access list integrated real-time switch ERTEC 400, 2xRJ45 Anschluss for LAN with 10/100 Mbit/s
Description
Transmission rate | ||
Transfer rate | ||
● at the 1st interface | 10 … 100 Mbit/s | |
Interfaces | ||
Number of interfaces / acc. to Industrial Ethernet | 2 | |
Number of electrical connections | ||
● at the 1st interface / acc. to Industrial Ethernet | 2 | |
Type of electrical connection | ||
● at the 1st interface / acc. to Industrial Ethernet | RJ45 port | |
design of the removable storage / C-PLUG | No | |
Supply voltage, current consumption, power loss | ||
Type of voltage / of the supply voltage | DC | |
Supply voltage / 1 / from backplane bus | 5 V | |
Relative symmetrical tolerance / at DC | ||
● at 5 V | 5 % | |
Consumed current | ||
● from backplane bus / at DC / at 5 V / typical | 1.4 A | |
Power loss [W] | 7.25 W | |
Permitted ambient conditions | ||
Ambient temperature | ||
● during operation | 0 … 60 °C | |
● during storage | -40 … +70 °C | |
● during transport | -40 … +70 °C | |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % | |
Protection class IP | IP20 | |
Design, dimensions and weight | ||
Module format | Compact module S7-400 single width | |
Width | 25 mm | |
Height | 290 mm | |
Depth | 210 mm | |
Net weight | 0.7 kg | |
Product properties, functions, components / general | ||
Number of units | ||
● per CPU / maximum | 14 | |
● Note | max. 4 as PN IO ctrl. | |
Performance data / open communication | ||
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 64 | |
Amount of data | ||
● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum | 2 Kibyte | |
Number of possible connections / for open communication | ||
● by means of T blocks / maximum | 64 | |
Amount of data | ||
● as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum | 1452 byte | |
Performance data / S7 communication | ||
Number of possible connections / for S7 communication | ||
● maximum | 128 | |
● with PG connections / maximum | 2 | |
● Note | when using several CPUs | |
Performance data / multi-protocol mode | ||
Number of active connections / with multi-protocol mode | 128 | |
Performance data / PROFINET communication / as PN IO-Controller | ||
Product function / PROFINET IO controller | Yes | |
Number of PN IO devices / on PROFINET IO controller / usable / total | 128 | |
Number of PN IO IRT devices / on PROFINET IO controller / usable | 128 | |
Number of external PN IO lines / with PROFINET / per rack | 4 | |
Amount of data | ||
● as user data for input variables / as PROFINET IO controller / maximum | 4 Kibyte | |
● as user data for input variables / as PROFINET IO controller / maximum | 4 Kibyte | |
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte | |
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte | |
● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte | |
● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte | |
Product function / MIB support | Yes | |
Protocol / is supported | ||
● SNMP v1 | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
Configuration software | ||
● required | STEP 7 V5.4 SP4 or higher | |
Product functions / Diagnosis | ||
Product function / Web-based diagnostics | Yes | |
Product functions / switch | ||
Product feature / Switch | Yes | |
Product function | ||
● switch-managed | No | |
● with IRT / PROFINET IO switch | Yes | |
● Configuration with STEP 7 | Yes | |
Product functions / Redundancy | ||
Product function | ||
● Ring redundancy | Yes | |
● Redundancy manager | Yes | |
● Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes | |
Protocol / is supported / Media Redundancy Protocol (MRP) | Yes | |
Product functions / Security | ||
Product function | ||
● password protection for Web applications | No | |
● ACL – IP-based | Yes | |
● ACL – IP-based for PLC/routing | No | |
● switch-off of non-required services | Yes | |
● Blocking of communication via physical ports | Yes | |
● log file for unauthorized access | No | |
Product functions / Time | ||
Product function / SICLOCK support | Yes | |
Product function / pass on time synchronization | Yes | |
Protocol / is supported | ||
● NTP | Yes |